LC1103
imagem meramente ilustrativa
-
5-Point Calibration with 59 kOhm Shunt Cal Data Included (Calibrated in Tension)
-
0.25% Interchangeability for Multiple Cell Load Applications
-
Dual Bridge Models Available
-
High Accuracy
-
Environmentally Protected
-
See Related Links Below for Cables and Accessories
Células de Carga - Ver Produtos Relacionados
Descrição
This item is discontinued.
SPECIFICATIONS
Excitation: 10 Vdc (15 Vdc max)
Output: 2 mV/V ±0.25% FSO
5-Point Calibration (in Tension): 0%, 50%, 100%, 50%, 0%
Protection Class: IP67
Linearity:
≤10 k: ±0.05% FSO
>10 k: ±0.1% FSO
Hysteresis: ±0.05% FSO
Repeatability: ±0.05% FSO
Zero Balance: ±1% FS
Operating Temp Range:
LC1103: -46 to 107°C (-50 to 225°F)
LC1113: -46 to 121°C (-50 to 250°F)
Compensated Temp Range: 16 to 71°C (60 to 160°F)
Thermal Effects:
Zero: ±0.0018% FS/°C
Span: ±0.0018% rdg/°C
Safe Overload: 150% of rated capacity
Ultimate Overload: 300% of rated capacity
Input Resistance: 350 ± 10 Ω
Output Resistance: 350 ±10 Ω
FS Deflection: 0.08 to 0.13 mm (0.003 to 0.005") typical
Construction: stainless steel
Electrical: 4.6 m (15') 4-conductor shielded color-coded PVC cable
Protection Class: IP67