Frequency Meter, Tachometer and Rate Meter
1/8 DIN - Discontinued

DP2000-H Series

Frequency Meter, Tachometer
and Rate Meter, 1/8 DIN | DP2000-H Series

Frequency Meter, Tachometer and Rate Meter, 1/8 DIN

imagem meramente ilustrativa

1 ano de garantia
  • ±1999 or ±9999 Count Display Span
  • Input of 100 Hz to 20 kHz for Full-Scale Display
  • Recorder Output
  • Front-Panel Accessible Adjustments
  • LED or LCD Display
  • Display Hold and Test
  • Screw-Terminal Barrier Strip

Descrição

Starting from Apr 1st 2018, DP2000/9000 Series have been discontinued. As a possible substitute, please check out the DPPT Panel Meter or DP20 Series for details.

The DP2000-H and DP9000-H are frequency meter/ tachometers with extensive zero and scale factor adjustment capability for direct readout in engineering units for RPM, flow and speed. Input frequencies can be as low as 100 Hz or as high as 20 kHz for the display maximum, which is 1999 for the DP2000-H and 9999 for the DP9000-H. Zero offset is available for use with transducers with a frequency output and a live zero. Choose any combination of display type (LED or LCD), operating power, input type and range, analog output, and digital or control outputs.

Easy to Interface
The meters are designed for easy interfacing to transducers with a frequency or pulse output. These include turbine flowmeters, passive magnetic pickups, and active proximity detectors with NPN, PNP or NAMUR (1 mA/3 mA) output. To accommodate different signal levels and provide noise immunity, the DC trigger level can be adjusted from -1 to 5V, and two hysteresis levels are selectable. Signals as low as 15 mV p-p or as high as 130 V rms can be monitored directly.

Configuration and Calibration
The units can be configured and scaled in the field. Adjustments for zero, span, and trigger level are accessible from the front panel to allow final calibration or recalibration without removal of the meter from the panel. The meters can be scaled to read RPM directly. With the dual-setpoint controller (optional), they can provide under and overspeed alarms. The 1 mV/ count analog output (standard) can be used to drive a strip-chart recorder for permanent. user-selected display span.

SPECIFICATIONS
Conversion
Technique: Dual slope, average value
Signal Integration Period: 100 ms, nominal
Reading Rate: 2.5/s, nominal
Display
Symbol: -1.9.9.9 (DP2); -8.8.8.8 (DP9)
LED: Red, 14.2 mm (0.56"), 7-segment
LCD: 12.7 mm (0.50"), 7-segment Power
AC Models: 120, 240 or 24 Vac 10/-15%, 49 to 440 Hz
DC Models: 5 Vdc ±5%, 9 to 32 Vdc or 26 to 56 Vdc isolated to 300 Vp
Common Mode
Voltage: 1500 Vp test (354 Vp per IEC spacing)
Rejection (DC to 60 Hz): 120 dB
Signal Input
Configuration: Single-ended
Input Resistance: 150 kΩ
Maximum Signal: 130 V rms Minimum Signal, 10 mV Hysteresis
Setting: 15 mV p-p, 100 Hz to 2 kHz (full scale); 30 mV p-p, 2 to 5 kHz (full scale); 90 mV p-p, 5 to 20 kHz (full scale) Minimum Signal; 100 mV Hysteresis
Setting: 125 mV p-p, 100 Hz to 5 kHz (full scale);175 mV p-p, 5 kHz to 20 kHz (full scale)
Hysteresis: 10 or 100 mV
Trigger Level: -1 to 5V with 100 mV hysteresis or -0.1 to 0.5V with 10 mV hysteresis
Signal Types: TTL logic, CMOS logic, open-collector, 2-wire NPN, 3-wire NPN, 3-wire PNP, 2-wire NAMUR, passive magnetic
Environmental
Operating Temperature: 0 to 60°C (32 to 140°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Humidity: 95% RH, non-condensing @ 40°C (104°F)
Mechanical
Bezel: 96 W x 48 H x 8 mm D (3.78 x 1.89 x 0.31")
Depth Behind Bezel: 139.8 mm (5.50")
Panel Cutout: 92 W x 45 mm H (3.62 x 1.77")
Weight: 17 oz (480 g)
Case Material: 94V-0 UL-rated polycarbonate