Ohmmeter Indicator/Controller - Discontinued

DP2000-0/DP9000-0 Series

Ohmmeter Indicator/Controller | DP2000-0/DP9000-0 Series

Ohmmeter Indicator/Controller

imagem meramente ilustrativa

1 ano de garantia
  • 1999 or 9999 Count Display Span
  • Ranges from 19.99 ohm to 19.99 kohm (DP2000)
  • Ranges from 999.9 ohm to 9.999 kohm (DP9000)
  • Front-panel accessible zero and span adjust
  • 1 mV or 0.1 mV/count Analog Output
  • LED or LCD Display
  • Display Hold and Test
  • Screw-Terminal Barrier Strip
  • Analog Outputs Available
  • Proportional Control Available

Descrição

Starting from Apr 1st 2018, DP2000/9000 Series have been discontinued. As a possible substitute, please check out the DPPT Panel Meter or DP20 Series for details.

The DP2000/9000-O is a panel mount resistance meter with direct readout in ohms. Resistance ranges are jumper selectable. It is complete with current excitation and open resistance detection. With the addition of analog and control outputs, it can be incorporated as a system component in ATE and closed-loop control applications.

Power and Display Options
Six types of power supplies are available: 120 Vac, 240 Vac, 24 Vac, 5 Vdc, isolated 9 to 32 Vdc and isolated 26 to 56 Vdc. An LED display is standard, an LCD display is optional and is recommended for viewing in bright ambient light. A NEMA (IP65) 4 splash-proof lens cover is available.

Signal input and power connections are made via a rear barrier terminal strip. The motherboard rear edge connector provides access to hold and test, polarity, clock, and the standard analog output and optional analog outputs. Decimal point positions can be selected by jumpers.

Analog Output Options
A 1 mV/count (±2 V full-scale) or 0.1 mV/count (±1 V full-scale) analog output is standard and is ideal for driving a strip-chart recorder. An additional analog output can be provided by an optional vertical plugin board. Available output signals are 0 to 5 Vdc, 0 to 10 Vdc, 0 to 1 mA (source or sink) and 4 to 20 mA (source or sink). The top and bottom of each output range can be scaled to fit a user-selected display span.

Control Output Options
Additional outputs can be provided by a horizontal upper board. Available options include single-setpoint control with one 10 A relay, dual-setpoint control with two 10 A relays, 4 to 20 mA proportional control (source or sink), time-proportional 2 A solid-state relay control, and isolated, parallel BCD output.

SPECIFICATIONS
Input Configuration
Connection: 2- or 4-wire
Zero Adjustment: ±50 counts
Overvoltage Protection (Differential): 15 Vp
Open-Circuit Voltage (maximum): 12V
Conversion
Technique: Dual slope, average value
Signal Integration Period: 100 ms, nominal
Reading Rate: 2.5/s, nominal
Display
LED: Red, 14.2 mm (0.56"), 7-segment
LCD: 12.7 mm (0.50"), 7-segment
Power
AC Models: 120, 240, or 24 Vac 10%/-15%, 49 to 440 Hz
DC Models: 9 to 32 Vdc, isolated to 300 Vp; 26 to 56 Vdc, isolated to 300 Vp; 5 Vdc ±5%, non-isolated
Common Mode
Voltage: 1500 Vp test (354 Vp per IEC spacing)
Rejection (DC to 60 Hz): 120 dB
Environmental
Operating Temperature: 0 to 60°C (32 to 140°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Humidity: 95% RH, non-condensing @ 40°C (104°F)
Mechanical
Bezel: 96 W x 48 H x 8 mm D (3.78 x 1.89 x 0.31")
Depth Behind Bezel: 139.8 mm (5.50")
Panel Cutout: 92 W x 45 mm H (3.62 x 1.77")
Weight: 17 oz (480 g)
Case Material: 94 V-0 UL-rated polycarbonate
We noticed you are from the US. Visit your local site for regional offers and live support.