Process Receiver Indicator/Controller
1/8 DIN - Discontinued

DP2000-P, DP2000-E Series

Process Receiver Indicator/Controller, 1/8 DIN | DP2000-P, DP2000-E Series

Process Receiver Indicator/Controller, 1/8 DIN

imagem meramente ilustrativa

1 ano de garantia
  • 10 or 15 Vdc Excitation Output (DP2000-E, DP9000-E)
  • ±1999 or ±9999 Count Display Span
  • Selectable Current Ranges From ±1 to ±50 mA
  • Selectable Voltage Ranges From ±0.5 to ±20 V
  • Built-In Shunts and Attenuators
  • Zero Adjustment to ±100% of Readout
  • Standard Signal Ranges of 4 to 20 mA, 10 to 50 mA, 1 to 5V or 0 to 10V
  • Front-Panel Accessible Zero and Span Adjust
  • 1 or 0.2mV/Count Analog Output
  • LED or LCD Display
  • Automatic Polarity
  • Display Hold and Test
  • Screw-Terminal Barrier Strip

Descrição

Starting from Apr 1st 2018, DP2000/9000 Series have been discontinued. As a possible substitute, please check out the DPPT Panel Meter or CNPT Controller for details.

The DP2000-P, DP9000-P is a process receiver with extensive zero and span adjustment capability for readout in engineering units. The more popular process signals are 4 to 20 mA, 10 to 50 mA, 1 to 5V and 0 to 10V. The DP2000-P, DP9000-P can also be scaled for other signal levels. Full-scale input ranges are selectable from ±1 to ±50 mA (current signal) or ±0.5 to ±20 V (voltage signal). Zero is adjustable up to ±100% of full-scale readout for every input range. A universal 1/8 DIN case houses each meter. Choose any combination of display type (LED or LCD), operating power, input type and range, analog output, and digital or control outputs.

The DP2000-E, DP9000-E is an enhanced version of the DP2000/DP9000-P with an excitation output for powering transmitters and active transducers. In many cases, this output can eliminate the need for a more expensive external supply. The output shares the ground of the signal input. Two output levels are jumper-selectable: 10 Vdc at up to 50 mA and 15 Vdc at up to 25mA.

Configuration and Calibration
The DP2000/DP9000-P and DP2000/DP9000-E includes configuration and calibration. Models can also be configured and scaled in the field. Full-scale signal, coarse-span and coarse-zero ranges are selected by plug-in jumpers. A complete set of internal shunts and attenuators are already on board. Fine-zero and fine-span potentiometers are accessible behind the lens to allow final calibration or field recalibration without removal of the panel meter.

SPECIFICATIONS
Conversion
Technique: Dual slope, average value
Signal Integration Period: 100 ms, nominal
Reading Rate: 2.5/s, nominal
Display
LED: Red, 14.2 mm (0.56"), 7-segment
LCD: 12.7 mm (0.50"), 7-segment
Power
AC Models: 120, 240 or 24 Vac 10%/ -15%, 49 to 440 Hz
DC Models: 9 to 32 Vdc, isolated to 300 Vp; 26 to 56 Vdc, isolated to 300 Vp; 5 Vdc ±5%, non-isolated
Common Mode
Voltage: 1500 Vp test (354 Vp per IEC spacing)
Rejection: 120 dB
Accuracy at 25°C
Error, Maximum: ±0.05% of reading ±1 count (DP2000); ±2 counts (DP9000)
Span Tempco: ±0.01% of reading/°C
Zero Drift, Maximum: ±0.01% of reading/°C
Offset Drift, Maximum: ±(0.01% offset V ±0.01% full scale V)/°C
Step Response: 1 s to 99.9% of span
Warmup to Rated Accuracy: 10 minutes (DP2000); 30 minutes (DP9000)
Environmental
Operating Temperature: 0 to 60°C (32 to 140°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Humidity: To 95% RH, non-condensing @ 40°C (104°F)
Mechanical
Bezel: 96 W x 48 H x 8 mm D (3.78 x 1.89 x 0.31")
Depth Behind Bezel: 139.8 mm (5.50")
Panel Cutout: 92 W x 45 mm H (3.62 x 1.77")
Weight: 17 oz (480 g)
Case Material: 94V-0 UL-rated polycarbonate