High Accuracy, High Pressure, Low-Flow Meters

FTB500 Series

High Accuracy, High Pressure, Low Flowmeters | FTB500 Series

High Accuracy, High Pressure, Low Flowmeters

imagem meramente ilustrativa

1 ano de garantia RoHS
  • 1% of Rate Accuracy
  • 1000 psig, 5000 psig Optional
  • For Flows Down to 0.02 GPM
  • Includes dc or ac Powered Signal Conditioner
  • Linear Pulse and Analog Outputs
Medidores de Vazão tipo Turbina e tipo Rotor - Ver Produtos Relacionados

Descrição

FTB500 series low flowmeters offer extremely accurate low flow measurement of liquids. They utilize a pelton wheel-like rotor whose motion is converted by a pickup coil into a pulse output that is proportional to flow . Each flowmeter comes with an integral signal conditioner, powered by either 15-35 Vdc or 115 Vac (opt.) to provide amplified frequency and analog outputs. The signal conditioner corrects for the inherent zero offset of the flowmeter pulse output. It is mounted in a NEMA-4, explosion-resistant enclosure rated for class I, groups C & D, class II, groups E, F, and G.

SPECIFICATIONS
Accuracy: ±1% of rdg for pulse, ±0.05% FS for analog outputs
Analog Output Response Time: adjustable from 0.5 to 2 seconds
Viscosity: 0.8 to 25 cSt, unit calibrated to specific viscosity value
Repeatability: ±0.25% of rdg
Fluid Temperature Range: -268 to 232°C (-450 to 450°F)
Operating Ambient Temperature: -20 to 80°C (-4 to 176°F)
Materials of Construction: 316 SS housing, 440C ball bearings, 17.4 PH rotor, and Rulon-J seals
Connections: ½" 37° flare per MS-33656-8; ½ MNPT adaptor kit opt.
Max Pressure Drop (at 1cSt): 10 psid
Max Pressure: 1000 psig std, 6000 psig optional
TTL Frequency Output: 0 to 125 Hz
Power: 15 to 35 Vdc std, 115 Vac optional
Analog Output: 4 to 20 mA into 375 Ω max std, 0 to 5 Vdc optional
Weight: 2.7 kg (6 lb)

ALL MODELS ARE CUSTOM, PLEASE CONSULT FULL SPECIFICATION PAGE FOR DETAILS.