Vane Anemometer with Real Time Data Logger

HHF-SD2

Vane Anemometer with Real Time Data Logger | HHF-SD2

Vane Anemometer with Real Time Data Logger

imagem meramente ilustrativa

1 ano de garantia CE
  • Low Friction Ball Bearing Vane
  • Type K or J Thermocouple Input
  • Real Time SD Memory Card Data Logger
  • LCD with Green Backlight
  • Velocity and Air Temperature Measurements
  • RS232/USB Interface (Optional Cable)
Indicadores de Velocidade de Ar e Túneis de Vento - Ver Produtos Relacionados

Descrição

The OMEGA™ HHF-SD2 combination vane and standard thermistor anemometer with SD card data logger has multiple features that make it suitable to use in such applications as air conditioning and heating systems, measuring air velocities and wind temperature. What sets the HHF-SD2 apart from other vane anemometers is that it incorporates a real-time SD card data logger.

The HHF-SD2 measures velocity, and air temperature, and has an input socket that accepts a Type J or K thermocouple that can be used as a highly accurate thermometer. The vane and standard thermistors provide high accurate readings at high velocities.

The HHF-SD2 is innovative and easy to operate. Download data from the SD card into an Excel spreadsheet without the need for special software.

SPECIFICATIONS
Display:
52 x 38 mm (2.05 x 1.50") LCD with green backlight (on/off)
Measurement Units:
    Velocity: m/s, km/h, ft/min, knots, mile/hr
    Temperature: °C or °F
Sampling Time:
    Auto: 1 to 3600 seconds
    Manual: Push the data logger button once, will save data one time
Memory Card: SD memory card (with optional SD card)
Temperature Compensation: Automatic
Display Update: At 1 second
Data Output:
    RS232: With optional cable/software
    USB: With optional cable/software
Operating Temperature: 0 to 50°C (32 to 122°F)
Operating Humidity: Less than 85% RH
Power: 6 “AAA” alkaline or heavy-duty batteries (included), or 9V power adaptor (optional)
Current Draw: 15 mA DC (without SD card or backlight), 36 mA (all functions)
Weight: 515 g (1.13 lb)
Dimensions:
    Instrument: 203 L x 76 W x 38 mm D (8 x 3 x 1.50")
    Probe: 72 mm dia (2.83")
Air Temperature:
    Measuring Range: 0 to 50°C (32 to 122°F)
    Resolution: 0.1°C (0.1°F)
    Accuracy: ±0.8°C (1.5°F)
We noticed you are from the US. Visit your local site for regional offers and live support.