  • Large Led Display Readable to 21 m (70')
  • Digital Input Module; Count and Rate Input Serial Slave
  • Alarms, Analog Output, and Communication
  • Programmable User Inputs
  • Programmable Function Keys
  • PC Software for Meter Configuration
  • NEMA 4 (IP65)

Descrição

The LDPF63000 model has been discontinued. Please see the LDP1 Series as a possible alternative or contact our Flow Engineering department.

The LDPF63000 Display is a versatile display that can increase productivity by offering the plant floor or production area a large visual display of their current status. Whether your measurement is rate or count, the LDPF63000 can satisfy your requirement. These LDPF63000 displays accept various digital inputs through the use of input modules that allow the unit to adapt to most any application. Additional plug-in option cards can add alarms, analog output, and communication/bus capabilities, making the LDPF63000 a truly intelligent panel meter.

SPECIFICATIONS
Rate Display
Accuracy: ±0.01%
Min Frequency: 0.01 hz
Max Frequency: see max signal frequencies table
Max Display:
5 Digits: 99999 Adjustable Display (Low) Update: 0.1 to 99.9 seconds Counter Displays
Maximum Display:
8 Digits: ± 99999999 (greater than 6 digits display alternates between high order and low order)
Inputs A and B
DIP switch selectable to accept pulses from a variety of sources including switch contacts, TTL outputs, magnetic pickups and all standard sensors.
Logic: Input trigger levels VIL = 1.5V max; VIH = 3.75V min
Current Sinking: Internal 7.8 K pull-up to 12 Vdc, IMAX = 1.9 mA
Current Sourcing: Internal 3.9 K pull-down, 7.3 mA max @ 28 Vdc, VMAX = 30 Vdc
Filter: Damping capacitor provided for switch contact bounce. Limits input frequency to 50 hz and input pulse widths to 10 msec minimum
Magnetic Pickup
Sensitivity: 200 mV peak
Hysteresis: 100 mV
Input Impedance: 3.9 K @ 60 hz
Max Input Voltage: ±40V peak, 30 Vrms
Dual Count Modes: When any dual count mode is used, then user inputs 1 and/or 2 will accept the second signal of each signal pair. The user inputs do not have the Logic/Mag, High/Low Freq, and Sink/Source input setup switches. The user inputs are inherently a logic input with no low frequency filtering. Any mechanical contacts used for these inputs in a dual count mode must be debounced externally. The user input may only be selected for sink/source by the user jumper placement.
Prescaler Output
NPN Open Collector: ISNK = 100 mA max @ VOL = 1 Vdc max VOH = 30 Vdc max with duty cycle of 25% min and 50% max
Display: 38 mm (1.5") red LED
Power (AC Modules): 85 to 250 Vac, 50/60 hz, 18 VA
Annunciators: A, B, C, SP1, SP2, SP3, and SP4
Keypad: Five tactile membrane switches integrated into the front panel
Enviromental Conditions
Operating Temperature Range: 0 to 45°C (32 to 113°F)
Storage Temperature Range: -40 to 60°C (-40 to 15°F) Operating and Storage Humidity: 0 to 85% max RH (non-condensing)
Altitude: Up to 2000 m (6562')
Mounting Requirements
Max panel thickness is 9.5 mm (0.375") Min panel thickness for NEMA 4 (IP65) sealing is 1.57 mm (0.060")
Connections: All wiring connections are made to the module via high compression cage-clamp terminal blocks. Wiring instructions are provided.
Construction: Steel front panel, enclosure, and rear cover with textured black polyurethane paint for scratch and corrosion resistance protection. Sealed front panel meets NEMA 4 (IP65) specifications for indoor use when properly installed. Installation Category II, Pollution Degree II. Panel gasket and keps nuts included.
Weight: 1.2 kg (2.7 lbs) (less module)

OPTION BOARDS SPECIFICATIONS
RS485 Communication Card:(LDP6-CDC10 or LDP6-CDC1C)
Type: RS485 multi-point balanced interface Isolation to Sensor and User
Input Commons: 500 Vrms for 1 min
Working Voltage: 50V not isolated from all other commons
Baud Rate: 300 to 19.2k
Data Format: 7/8 bits; odd, even, or no parity
Bus Address: 0 to 99, max 32 meters per line
Transmit Delay: Selectable 2 to 50 msec or 50 to 100 msec
RS232 Communication Card (LDP6-CDC20 or LDP6-CDC2C)
Type: RS232 half duplex Isolation to Sensor and User
Input Commons: 500 Vrms for 1 min
Working Voltage: 50V not Isolated from all other commons
Baud Rate: 300 to 19.2k
Data Format: 7/8 bits; odd, even or no parity
Modbus Communications Card (LDP6-CDC40 or LDP6-CDC4C)
Type: RS485; RTU and ASCII MODBUS modes Isolation to Sensor and User Input
Commons: 500 Vrms for 1 minute
Working Voltage: 50V not isolated from all other commons
Baud Rates: 300 to 38400
Data: 7/8 bits
Parity: No, odd, or even
Addresses: 1 to 247
Analog Output Card (LDP6-CDL)
Types: 0 to 20 mA, 4 to 20 mA and 0 to 10 Vdc Isolation to Sensor and User Input
Commons: 500 Vrms for 1 min
Working Voltage: 50V not isolated from all other commons
Accuracy: 0.17% of FS (18 to 28°C); 0.4% of FS (0 to 50°C)
Resolution: 1/3500
Compliance:
10 Vdc: 10 KΩ load min
20 mA: 500 Ω load max
Update Time: 200 msec max to within 99% of final readout value (digital filter and internal zero correction disabled) 700 msec max (digital filter disabled, internal zero correction enabled)
LDP63000-AC: 1 sec max to within 99% of final readout value (digital filter disabled)
Setpoint Output Cards (Four Types of Field Installable Cards)
Response Time: 200 msec max to within 99% of final readout value (digital filter and internal zero correction disabled)700 msec max (digital filter disabled, internal zero correction enabled)
LDP63000-AC Only: 1s max to within 99% of final readout value (digital filter disabled)
LDP63000-T Only: 200 msec typ.; 700 msec max (digital filter disabled)
Dual Relay Card (LDP6-CDS10)
Type: Two FORM-C relays Isolation to Sensor and User Input
Commons: 2000 Vrms for 1 min
Working Voltage: 250V
Contact Rating:
One Relay Energized: 5 Amps @ 120/240 Vac or 28 Vdc (resistive load), 1.8 HP @120 Vac, inductive load total current with both relays energized not to exceed 5 Amps
Life Expectancy: 100K cycles min at full load rating. External RC snubber extends relay life for operation with inductive loads.
Quad Relay Card (LDP6-CDS20)
Type: Four FORM-A relays Isolation to Sensor and User Input
Commons: 2300 Vrms for 1 min
Working Voltage: 250 Vrms
Contact Rating:
One Relay Energized: 3 Amps @ 250 Vac or 30 Vdc (resistive load), 1.10 HP @120 Vac, inductive load total current with all four relays energized not to exceed 4 Amps
Life Expectancy: 100K cycles min at full load rating. External RC snubber extends relay life for operation with inductive loads.
Quad Sinking Open Collector (LDP6-CDS30)
Type: Four isolated sinking NPN transistors Isolation to Sensor and User
Input Commons: 500 Vrms for 1 min
Working Voltage: 50V not isolated from all other commons
Rating: 100 mA max @ VSAT = 0.7V max Vmax = 30V Quad Sourcing Open Collector (LDP6-CDS40)
Type: Four isolated sourcing PNP transistors Isolation to Sensor and User
Input Commons: 500 Vrms for 1 min
Working Voltage: 50V not isolated from all other commons
Rating:
Internal Supply: 24 Vdc ±10%, 30 mA max total all four
External Supply: 30 Vdc max, 100 mA max each output
Programming Software
(Free download) Allows configuration of the LDPF63000 meter from a PC. This software offers standard drop-down menu commands, that make it easy to program the meter. The unit program can then be saved in a PC file for future use. A serial plug-in card is required to program the meter using the software.