Frequency Output Pressure Transducers  - Discontinued

PX106-F Series

Frequency Output Pressure Transducers | PX106-F Series

Frequency Output Pressure Transducers

imagem meramente ilustrativa

RoHS
  • 10-20 Vdc Excitation
  • 0.5% Linearity
  • -40° to +85°C Operation
  • Valox Outer Case
  • Stainless Steel Chamber
  • ±1% FS Accuracy
Transdutores de Pressão - Ver Produtos Relacionados

Descrição

The PX106 series has been discontinued. Please contact our Pressure Engineering department.

SPECIFICATIONS
Excitation: 10 to 20 Vdc at 30 mA
Output: 1 to 6 kHz
Accuracy: ±1% full scale typical, ±2% full scale max
Linearity : <50 psi ±0.5%; ≥50 psi ±0.2% FS
Hysteresis: ±0.25% full scale
Zero Balance: ±1% typical, ±2% max Compensated Temperature Range: 0 to 85°C (32 to 185°F)
Thermal Zero Effect: ±0.02%/°C (±0.01% rdg/°F)
Thermal Sensitivity Effect: ±0.02%/°C (±0.01% rdg/°F)
Proof Pressure: 2x full scale
Burst Pressure: 5x full scale min
Gages: Piezoresistive on bending beam
Diaphragm/Port Material: 300 Series SS (silver, copper, nickel, cadmium brazed)
Electrical Connection: CX-106-4
Weight: 114 g (4 oz)
Media Compatibility: Typical media include oil, gases, saline solutions, ammonia, freon, hydraulic fluids, alcohol, acids, and gasoline