  • K, J, N, E, T, R, S Thermocouples and mV Inputs
  • Pushbutton Configuration
  • 56 Preprogrammed Ranges Ready-to-Use
  • User Trim - Null Out Sensor Error
  • Programmable Burnout with Sensor Fail Indicator
  • Galvanically Isolated
Intrumentos para Medição e Controle de Processos - Ver Produtos Relacionados

Descrição

The TX13 is a "smart" and galvanically isolated in head transmitter that accepts thermocouple temperature sensors and converts sensor output over a configured range to a standard industrial (4 to 20 mA) transmission signal. A simple push button operation allows the user to select TC type, burnout direction, select fixed ranges and trim 4 and 20 mA points. The in head transmitter incorporates the latest digital technology to ensure accurate drift-free performance. If required the desired range can be specified at the time of order, removing the need for user configuration. If the range is not specified then the transmitter will be shipped with the default range of 0 to 1000°C (32 to 1832°F) Type K.

SPECIFICATIONS
Isolation: Tested to 250 Vdc
Sensor Burnout: Either up or down scale output
Cold Junction:
    Range: -40 to 85°C (-40 to 185°F)
    Accuracy: ±0.5°C (33°F)
    Tracking: ±0.05°C/°C (32°F/°F)
Stability:
    Offset: 0.1°C/°C (32°F/°F)
    Span: 0.05°C/°C (32°F/°F)
Output
Output Type: 2 wire, 4 to 20 mA current loop
Output Range: 4.0 to 20.0 mA
Output Connection: Screw terminal
Maximum Output: 21.5 mA (in high burnout condition)
Minimum Output: 3.8 mA (in low burnout condition)
Accuracy: (mA output /2000) or 5 uA (whichever is the greater)
Loop Voltage Effect: 0.2 uA/V
Thermal Drift: 1 uA/°C
Maximum Output Load: [(Vsupply-10)/20]KΩ (Example: 700Ω @ 24V)
Update Time: 500 mS
Response Time: 1 second
Start Up Time: 4 seconds (1 out < 4 mA during start up)
Warm-Up Time: 1 minutes to full accuracy
Power Supply: 10 to 30 Vdc
Environmental
Ambient Operating Range: -40 to 85°C (-40 to 185°F)
Ambient Storage Temperature: -50 to 90°C (-58 to 194°F)
Ambient Humidity Range: 10 to 90% RH non condensing
Physical Dimensions: 43 mm Dia; 21 mm H (1.7"; 0.8")
Weight: 31 g (0.07 lbs) (encapsulated)
Approvals
EMC - BS EN 61326 :1998: Electrical equipment for measurement control and laboratory use
ANNEX A: Immunity test requirements for equipment intended for use in industrial locations

Specifications @ 20°C-Input
Sensor Range °C(°F) Accuracy
K-200 to 1370(-328 to 2498)±0.5°C (1°F) or ±0.1% which ever the greater
J-100 to 1200(-148 to 2192)±0.5°C (1°F) or ±0.1% which ever the greater
E-100 to 1000(-148 to 1832)±0.5°C (1°F) or ±0.1% which ever the greater
N-180 to 1300(-292 to 2372)±0.5°C (1°F) or ±0.1% which ever the greater
T-100 to 400(-148 to 752)±0.5°C (1°F) or ±0.1% which ever the greater
R-10 to 1760(14 to 3200)±0.5°C (1°F) or ±0.1% which ever the greater over range 800 to 1600
S-10 to 1760(14 to 3200)±0.5°C (1°F) or ±0.1% which ever the greater over range 800 to 1600
mV-10 to 70(14 to 158)±0.02% of full scale
We noticed you are from the US. Visit your local site for regional offers and live support.