Definite Purpose Contactors

C25 Series

Definite Purpose Contactors | C25 Series

Definite Purpose Contactors

imagem meramente ilustrativa

CE
  • Open Style with Metal Mounting Plate
  • 1-, 2- and 3-Pole Models
  • 25 to 75 A Capacity
  • Kits for Side Auxiliary Contact
  • NEMA 1 Enclosure Available
Relés e Temporizadores - Ver Produtos Relacionados

Descrição

Cutler-Hammer definite purpose (DP) contactors are designed to improve control of refrigeration, air conditioning, ventilation and resistance heating applications. The complete line offers everything from compact DPs to the smallest 50 ampere DP contactor in the world an average of 20% smaller than the competition. Always looking for new ways to improve the customer experience, the 50 mm (2") DP contactor with an innovative sealed housing is designed to keep out contaminants and lower noise. Building on that success, the new series of Compact DPs are now available in a sleek new sealed design. Continuing to innovate and upgrade products, Eaton offers the perfect definite purpose solution for your HVACR applications.

New Compact Models Definite Purpose Contactors
The new 30 ampere, single- and double-pole, Type C25 compact DP contactors feature a compact, efficient design with a low VA coil and straight through wiring. These devices are economically priced, UL recognized/CSA certified, are current rated and hp/kW rated with magnet coils rated Class F, 155°C (311°F) [most are Class B, 130°C (266°F)] and designed with low VA current ratings for less energy consumption. With the ability to be mounted vertically, horizontally or tabletop, the new series of compact DPs will meet all your definite purpose application needs.
SPECIFICATIONS
COMPACT MODELS
UL Recognized Components: UL File number E1491, Guides NLDX2 and NLDX8
CSA Certified Components: CSA C22.2 No. 14-05, File number 238083 Class 3211 84
IEC: 60947-4-1
EN: 60947-4-1
ARI: 780/790 Standard
RoHS: Compliant
Insulation Voltage: 690V Current Rated and hp/kW Rated
Contacts: Double break
Magnet Coil: Class F, 155°C (311°F)
Contact Arc Covers: Standard on all contactors
Contactors are Marked with Line and Load Terminal Designations Operating Temperature Range: -13 to 158°F (-25 to 70°C)

TERMINAL WIRE RANGE
Hex Washer Head Screws: 16-10 AWG, 30 lb-in torque rating
Box Lugs:
    16-10 AWG: 35 lb-in torque rating
    8 AWG: 40 lb-in torque rating
    6-4 AWG: 45 lb-in torque rating
Mounting Position: Vertical, horizontal or tabletop
We noticed you are from the US. Visit your local site for regional offers and live support.