Carrinho  |  Contato  |  Suporte  | 
Atendimento e Vendas 0800-773-2874
e-mail:vendas@br.omega.com

DIN Rail Mount AC Voltage/Current Signal Conditioners, 2-Wire Loop Powered Design

DRA-ACT-2 Series

DIN Rail Mount AC Voltage/Current Signal Conditioners, 2-Wire Loop Powered Design | DRA-ACT-2 Series

imagem meramente ilustrativa

Veja lista de preços e produtos abaixo

1 ano de garantia
  • DRA-ACT-2I Series AC Current Input
  • DRA-ACT-2V Series AC Voltage Input
  • ± 0.1% Accuracy
  • Isolated
  • High Noise Immunity
  • Low Profile Enclosure
Transdutores de Corrente, Tensão e Watt/Var - Ver Produtos Relacionados

Descrição

The DRA-ACT-2I AND DRA-ACT-2V Series are isolated 2-wire loop-powered ac current and ac voltage input DIN rail mount signal conditioners that convert the measured input into a proportional, linear and highly accurate 4-20 mA output current. The DRA-ACT-2I Series of ac current input models includes models for 0 to1 Aac and 0 to5 Aac inputs with 4 to20 mA output. The DRA-ACT-2V Series of ac voltage input models includes models for 0 to150 Vac, 0 to250 Vac and 0 to400 Vac inputs again with 4 to 20 mA output.

For complete safety, an internal transformer isolates the signal conditioner input from the output thus enabling these units to withstand large momentary inputs. Complete input to output isolation, high surge current capacity and high output signal-to-noise ratio make these signal conditioners highly immune to ground loop signals and RFI. These transmitters are also equipped with a “test” terminal which facilitates monitoring of the output current by measuring the voltage drop across an internal 10 Ohm resistor without disturbing the 4 to 20 mA process loop.

Specifications

GENERAL
Accuracy: ±0.1% of span typical (2-100% of span) for pure sinusoidal input
Temperature Stability: ±0.015% of span /1°C
CMR: 122 dB typical; 117 dB min Response Time: 220 msec (0-98%)
Power Supply: 10-32 Vdc
Loop Resistance: Rmax (ohms) = (Vsupply 10)/0.02

SUPPLY AND LOAD
Variation Effect: < 0.03% for full change
Test Terminal: 40 to 200 mV represents 4 to 20 mA
Output Ripple: better than 0.1% of span RMS
Frequency: 40 to 500 Hz
Output: 4 to 20 mA
Zero Adjust: ±35% min
Span Adjust: ±25% min
Operating Ambient: 32 to 158°F (0 to 70°C); 5 to 95% RH, noncondensing
Storage Temperature: -13 to 185°F (-25 to 85°C)
Enclosure: polycarbonate
Mounting: standard 35 mm DIN rail or wall mount
Dimensions: 2.87" H x 1.28" W x 4.49" D (73 x 32.5 x 114 mm)
Weight: 0.5 lb (0.2 kg)

DRA-ACT-2I SERIES
(AC CURRENT INPUT)
Input: 0 to 1 Aac, 0 to 5 Aac
Input Power Consumption: 0.26 VA at 5 Aac input
Inrush Current: 40 Aac RMS max for 8 sec every 10 min; 75 Aac RMS max for 1 sec every 10 min DRA-ACT-2V
(AC VOLTAGE INPUT)
Input: 0 to 150 Vac, 0 to 250 Vac. 0 to 400 Vac
Input Power Consumption: 0.3 VA at 120 Vac input; 1.4 VA at 230 Vac input
Isolation: 2.5 KV RMS for one minute

Ver Modelos e Preços(Especifique o número do modelo)

O que outras pessoas compraram: Quando você vir este ícone, clique nele para expandir a lista de produtos que outras pessoas tenham comprado quando compraram este modelo.

Código de Produto/Desc.
Qtd
Descrição
Quick Ship
  
DRA-ACT-2I-1
Sob consulta  
Disponível em: 
 
 
ac current, 0 to 1 A ac input, 4 to 20 mA output
Quick Ship
Clique para expandir / minimizar uma lista do que os outros compraram comDRA-ACT-2I-2
DRA-ACT-2I-2
Sob consulta  
Disponível em: 
 
 
ac current, 0 to 5 A ac input, 4 to 20 mA output
Quick Ship
  
DRA-ACT-2V-1
Sob consulta  
Disponível em: 
 
 
ac voltage, 0 to 150 Vac input, 4 to 20 mA output
Quick Ship
  
DRA-ACT-2V-2
Sob consulta  
Disponível em: 
 
 
ac voltage, 0 to 250 Vac input, 4 to 20 mA output
Quick Ship
  
DRA-ACT-2V-3
Sob consulta  
Disponível em: 
 
 
ac voltage, 0 to 400 Vac input, 4 to 20 mA output
Quick Ship
Clique para expandir / minimizar uma lista do que os outros compraram comiDRN-PS-1000
iDRN-PS-1000
Sob consulta  
Disponível em: 
 
 
Power supply, 95-240 Vac input, 24 Vdc @ 1 A output
Preços indicados em Reais e já incluem todos os impostos e taxas de acordo com a legislação vigente. Nota: Comes with complete operator’s manual.