  • 0.05% Linearity
  • Internal Shunt Resistor for Easy System Checks
  • 5-Point NIST Traceable Calibration Provided
  • All Stainless Steel Construction
  • Hermetically Sealed Design for Harsh Environments
  • Available in Gage, Absolute and Sealed Gage Ranges
  • Cable or Connector Models
  • Optional Pressure Ports to Fit Most Industrial Applications
  • See Related Links Below for Cables and Accessories
Transdutores de Pressão - Ver Produtos Relacionados

Descrição

OMEGA's PX01 Series is a high accuracy, amplified voltage output, industrial pressure transducer. All stainless steel construction and a hermetically sealed case makes the PX01 suitable for harsh industrial environments. It is a true high accuracy industrial device. A broad temperature compensated range of 16 to 71°C (60-160°F) and excellent temperature compensation make this transducer very stable with fluctuating temperatures. The PX01 is available in gage, absolute or sealed models as well as PSI or metric ranges. NPT and 7/16-20 O-ring seal fittings are available for industrial and Hydraulic applications.


The PX01 is also available in metric configurations, with G1/4 or G1/8 ports, and models from 0-150 mbar to 0-400 bar pressure ranges. Please see the PXM01 for complete details, or contact our Pressure department for more information.

Consult sales for units available with Inconel construction.



SPECIFICATIONS
Excitation:
0 to 5 Vdc Output: 24 to 32 Vdc
4 to 20 mA Output: 10 to 40 Vdc
4 to 20 mA (Lightning protection only): 12 to 40 Vdc
Linearity:
mV/V: 0.10% FSO <500 psi
         0.05% FSO >=500 psi
All other models: 0.05% FSO
Hysteresis: 0.05% FSO
Repeatability: ±0.05% FSO
Shunt Calibration Value: Value specified on calibration sheet
Sensing Element: 4-active-arm bridge, using thick-film strain gages in a hermetically sealed chamber (except gage units)
Operating Temp Range: -46 to 121°C (-50 to 250°F)
mV/V Output: -73 to 163°C (-100 to 325° F)
Compensated Temp Range: 16 to 71°C (60 to 160°F)
Proof Pressure: 150% of rated pressure
Burst Pressure: 300% of rated pressure
Wetted Parts: 17-4 PH stainless steel
Pressure Port: See custom configurations
Electrical Connection:See custom configurations
Mating Connector: PT06F10-6S (sold separately)
OUTPUT
0 to 5 Vdc Output: ±10% ADJ.
4 to 20 mA Output: 4 to 20 mA ±10%ADJ.
mV/V Output: 3 mV/V ±0.25% <500 psi
2.75 mV/V ±0.25% >=500 psi
Zero Balance:
0 to 5 Vdc Output: 0 V ±10% ADJ.
4 to 20 mA: +4 mA +10% -2% ADJ.
mV/V Output: 1.0% FS
Thermal Effects:
Span:
mA Output: ±0.003% FSO/°F
5V: ±0.002% FSO/°F
mV/V: ±0.0015% FSO/°F
Zero:
mA Output: ±0.003% FSO/°F
5V: ±0.001% FSO/°F
mV/V: ±0.0015% FSO/°F
Weight: 388 g (13.7 oz)
mV/VOutput: 255 g (9 oz)
Input Resistance
(mV/V Output): 350 ±10 Ω
Output Resistance
(mV/V Output): 350 ±10 Ω



Compatible meters: DP41-E*, DP25-E*, DP24-E*