NEMA-4 Case Low Differential Pressure Transmitters
Discontinued Product
PX292
NEMA-4 CASE
imagem meramente ilustrativa
Current Output Models Available
Low Power Consumption
No Moving Parts to Wear
Position Insensitive
Reliable Long Term Stability
NEMA 4/IP65 Cast Aluminum Case
Descrição
The PX292 is no longer available. Please see the PX656 series as a possible
substitute or contact our sales department.
The PX292 Series of differential pressure transmitters is designed to measure low pressures while using little power. A selection of ranges is available to meet most industrial and laboratory applications. The transmitters are housed in a rugged, gasketed, cast-aluminum case thatfs designed to NEMA 4 and IP65 standards. Wall-mounting holes are in the casting. The terminals are accessed through 1.2" conduit knockouts on the front of the box. There are no moving parts and the transmitters are virtually position insensitive. The span and zero settings are made via 20-turn potentiometers for easy, precise adjustments. The pressure sensing element is a differential capacitive cell for the low pressure ranges from 0.1 to 5 inH2O and a piezoresistive chip for ranges above 5 inH2O. Both sensors ensure reliability and long-term stability.
SPECIFICATIONS General: Measures differential, gage pressure or vacuum Excitation: 11 to 32 Vdc reverse polarity protected Current Output: 4 to 20 mA, output limited to approximately 3.85 mA at low end and 27 mA at high end Maximum Current Loop Resistance: RL = (Vs - 11) x 50 Accuracy: ±1% includes linearity, hysteresis Calibration: NIST traceable Operating Temperature: 0 to 45°C (32 to 115°F) Temperature Effects: Zero: ±0.05%/°C Span: ±0.02%/°C Operating Humidity Range: 10 to 90% non-condensing Shock Resistance: 10 g (11 ms) Vibration Resistance: 5 g to 50 Hz Overpressure: See order chart for maximum safe momentary overpressure Media Compatibility: Suitable for air or inert gas Pressure Connection: 3.16" Dia. tube connections with integral filters at both ports. Suitable for 1.8" ID TygonR or polyurethane tubing (3-4 mm) or 1.4" OD polyethlene tubing (6 mm). Electrical Connection: Pluggable terminal block for 14 to 26 AWG Case Material: Aluminum alloy #A380 with black epoxy coating Dimensions: 90 W x 115 L x 55 mm H (3.56 x 4.54 x 2.18") Weight: 576 g (1.27 lb)
OFFSET OPTIONS If the measured differential pressure is expected to go from positive to negative, a transmitter with offset (elevated zero) should be ordered. The standard models in the order chart have no offset (i.e., at zero differential pressure, the output is 0 Vdc or 4 mA). Two offset options are available: gAh 1.4 Span Offset At zero differential pressure, the output is 1.25 Vdc or 8 mA. Allowable Pressure Excursion: -33% to 100% of range gBh 1.2 Span Offset At zero differential pressure, the output is 2.5 Vdc or 12 mA. Allowable Pressure Excursion: -100% to 100% of range PX292-001WDI-B will have a range of +1" water at 20 mA and -1" water at 4 mA.