  • Isolation and Conversion of Current Signals
  • Splitter Function: 1 Current Input—2 Current Outputs
  • Slimline Housing—Only 6 mm (0.24") Wide
  • Fast Response Time <7 ms
  • High Accuracy, <0.05% of Span
  • Easy-to-Use—No Setup Needed
Intrumentos para Medição e Controle de Processos - Ver Produtos Relacionados

Descrição

The DRSL-SP1 isolated repeater/ splitter provides a competitive choice in terms of both price and technology for galvanic isolation of current signals to SCADA systems or PLC equipment. Two current outputs are provided which mirror the single current input.

The DRSL-SP1 can be used for signal conversion of a standard process current signal into two individual analog signals. The unit offers 4-port isolation, provides surge suppression and protects control systems from transients and noise. The DRSL-SP1 also eliminates ground loops and can be used for measuring floating signals. Low power consumption facilitates DIN rail mounting without the need for any air gap. Measurement ranges are factory calibrated. The unit operates over a wide temperature range from -25 to 70°C (-13 to 158°F).

SPECIFICATIONS
CURRENT INPUT
    Measurement Range: 0 to 20.5 mA
    Functional Range: 0 to 23 mA
    Input Voltage Drop: <1.5 Vdc

CURRENT OUTPUT
Number of Outputs: 2
    Signal Range: 0 to 20.5 mA (span)
    Load: 23 mA/300 Ω maximum
    Load Stability: ≤0.01% of span/100 Ω (span = 0 to 20 mA)
    Current Limit: ≤28 mA

GENERAL
Supply Voltage (via Power Rail or Connectors): 16.8 to 31.2 Vdc
Power Consumption: 0.8 W max
Internal Consumption: 0.4 W typical/0.65 W max
Isolation: Input/output 1/ output 2/supply
Isolation Voltage (Test): 2.5 kVac
Isolation Voltage (Working): 300 Vac
Signal/Noise Ratio: > 60 dB
Response Time (0 to 90%, 100 to 10%): <7 ms
Accuracy: < ±0.05% of span
Temperature Coefficient: <±0.01% of span/°C
EMC Immunity Influence: < ±0.5% of span
Extended EMC Immunity
    NAMUR NE 21, A Criterion, Burst:
<±1% of span

ENVIRONMENTAL
Operating Temperature: -25 to 70°C (-13 to 158°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Calibration Temperature: 20 to 28°C (68 to 82°F)
Relative Humidity: 0 to 95% RH non-condensing
Protection Degree: IP20
Installation Area: Pollution degree 2 and measurement/overvoltage category II

MECHANICAL
Dimensions: 113 H x 6.1 W x 115 mm D (4.4 x 0.24 x 4.5")
Weight: 70 g (0.15 lb) approx
DIN Rail Type: DIN EN 60715 - 35 mm
Wire Size: 0.13 x 2.5 mm2/AWG 26 to 12 stranded wire
Screw Terminal Torque: 0.5 Nm
Ver Modelos e Preços(Especifique o número do modelo)

O que outras pessoas compraram: Quando você vir este ícone, clique nele para expandir a lista de produtos que outras pessoas tenham comprado quando compraram este modelo.

Código de Produto/Desc.
Qtd
RoHS
Descrição
Quick Ship
  
DRSL-SP1
R$1.310,00
Disponível em: Em estoque
conformidade RoHS
Isolated repeater/splitter for current signals
Accessories
Quick Ship
Clique para expandir / minimizar uma lista do que os outros compraram comDRSL-PWR-RAIL
DRSL-PWR-RAIL
R$955,00
Disponível em: Em estoque
conformidade RoHS
Power rail (with cover and two end covers, one right hand and one left hand), 1 m (3.3') length
Quick Ship
Clique para expandir / minimizar uma lista do que os outros compraram comDRSL-PCU
DRSL-PCU
R$695,00
Disponível em: Em estoque
conformidade RoHS
Power connector unit, 24 Vdc/2.5 A output to power rail
Quick Ship
  
DRSL-MOD-STOP
R$43,50
Disponível em: Em estoque
conformidade RoHS
Module stop (screwed onto power rail to support and hold mounted devices)
Preços indicados em Reais e já incluem todos os impostos e taxas de acordo com a legislação vigente. Exemplo de Pedido: (1) DRSL-MOD-STOP Module stop (screwed onto power rail to support and hold mounted devices), R$43,50  plus (1) DRSL-PCU Power connector unit, 24 Vdc/2.5 A output to power rail, R$695,00  plus (1) DRSL-PWR-RAIL Power rail (with cover and two end covers, one right hand and one left hand), 1 m (3.3') length, R$955,00  plus (1) DRSL-SP1 Isolated repeater/splitter for current signals, R$1.310,00, R$43,50 + 695,00 + 955,00 + 1.310,00 = R$3.003,50

Manuais:

Baixar Installation Guide for Signal Conditioners
Baixar DIN Rail Isolators and Signal Conditioners